Dialogic Brooktrout Digital Board Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Vernetzung Dialogic Brooktrout Digital Board herunter. Dialogic Brooktrout Digital Board Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Installing the
Dialogic® Brooktrout®
TR1034
Digital / Ethernet
Fax Board (Single Span)
Part Number: 931-101-05
The Dialogic
® Brooktrout® TR1034
Digital/Ethernet combination PCI fax boards
(“TR1034” or “TR1034 Fax Board(s)”) are full-sized,
single slot, PCI bus compatible boards with T1/E1,
Ethernet, and H.100 capabilities. The TR1034
delivers 33.6 Kbps (V.34) fax transmission speeds,
up to 30 fax channels per fax board, Adaptive Call
Progress, Error Correction Mode, MMR fax
compression, and an onboard T1/E1 interface (see
Figure 6). The Ethernet connector is used for T.38
Fax over IP.
The Dialogic® Brooktrout® TR1034 Fax Board has
access to off-board resources using the H.100 bus
interface. Using a bus adapter (available
separately), the H.100 can interoperate with an
MVIP or SCbus interface.
You need a separate fax application to use the
TR1034 Fax Board. Please contact your application
provider for the correct operating system driver,
supporting files, and firmware.
Operating/Environmental Specifications
This device must be installed in an enclosure that
meets the following electrical and mechanical
requirements.
Power requirements:
Base: 4 A at 5
VDC = 20 W
Base + Mezzanine: 5 A at 5 VDC = 25 W
Temperature: 0°C - 50°C
Humidity: 10% - 95% (noncondensing)
Cooling: Direct forced-air flow is required.
33 MHz PCI 2.2 Universal card (3.3/5V
signaling)
Setting the Module Number (SW1)
You must set each TR1034 Fax Board to a unique
module number to identify the resources associated
with a specific board in a multi-board system. SW1
(Figure 1) is a rotary switch (see location in
Figure 4). Use it to set the module number for each
TR1034 Fax Board. The available settings are 2 - F
(0 and 1 are reserved).
Figure 1 Rotary Switch - SW1
Using the H.100 Termination Switch (SW2)
On a single TR1034 or on multiple TR1034 Fax
Boards installed in the same chassis, leave SW2 in
the OFF position. See Figure 4 for its location.
Multiple TR1034 Fax Boards in the same system do
not require the use of a connecting H.100 cable.
If you have a TR1034 and other boards that need to
be connected using an H.100 cable (not supplied),
you must terminate the H.100 clock signal. Only the
boards at each end of the cable must be terminated.
All other boards must not be terminated (see
Figure 2).
Figure 4 Dialogic® Brooktrout® TR1034 Digital/Ethernet
PCI Fax Fax Board
Figure 2 Setting Clock Termination in a Series of Boards
Connected by an H.100 Bus
SW2 (see Figure 3) controls termination for the
H.100 clock signals. Set the switch to ON to
terminate the H.100 clock on a TR1034 Fax Board
(see Figure 4 for the location of the switch on the
board). The SW2 LED lights when SW2 is set to the
ON position.
Figure 3 SW2 - H.100 Clock Termination Switch
Installing the Dialogic® Brooktrout® TR1034
Fax Board
To install the board:
1. Power off the computer.
2. Remove the computer cover. If the system has a
board hold-down bar, remove it as well.
3. Locate an unused PCI expansion slot and
remove the blank bracket.
The TR1034 Fax Board comes with an extension
bracket that allows it to fit snugly into an ISA
form-factor chassis. If you have a PCI
form-factor chassis, use a Phillips-head
screwdriver to remove the extender bracket (see
Figure 4).
4. Holding the TR1034 Fax Board at each top
corner, insert the board firmly into the PCI slot,
sliding the extender into the side of the chassis,
if necessary.
5. Screw the board’s mounting bracket securely to
the computer's frame. See Figure 4.
6. Attach the connector on the H.100 cable to the
connector on the board, if needed.
7. Replace the computer cover.
8. Turn on the computer.
The board status LED (see Figure 4)
continuously flashes yellow when you turn the
computer on.
Note: Dialogic® Brooktrout® fax boards should not be
present in the computer during the installation of any
operating system. The operating system can
misinterpret the board as being some other device, with
unpredictable consequences.
Recognizing PCI Slots
The PCI connectors in the computer chassis usually
appear as white slots. The different variations of
PCI connectors that can be used with the TR1034
Set the H.100 switch
to the ON position.
Set the H.100 switch
to the ON position.
Set H.100 switches
on these boards to
the OFF position.
Push switch
toward board
to turn ON.
Caution: A small amount of static electricity can
destroy the sensitive components on your board.
To prevent static damage, always connect yourself
to ground using a ground strap before touching a
circuit board. Handle boards only by the edges or
metal mounting brackets and transport boards in
an anti-static bag.
Warning: When installing the board, be sure that
the mounting bracket is securely fastened to the
chassis and the chassis is plugged into a
grounded three prong plug. Improper chassis or
bracket grounding can result in harmful or fatal
electrical shock as well as component damage.
SW2 - H.100 Termination Switch
SW1 - Rotary Switch
Mounting Bracket
T1/E1 Connector A
T1/E1 Status LED A
Board Status LED
D23 - Termination Switch Indicator LED
H.100 Connector
Universal PCI Connector
ISA length chassis
extension bracket
*
These LEDs are for manufacturing purposes only.
LEDs
*
LEDs
*
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - Fax Board (Single Span)

Installing the Dialogic® Brooktrout® TR1034 Digital / Ethernet Fax Board (Single Span)Part Number: 931-101-05The Dialogic® Brooktrout® TR1034 Digital/

Seite 2 - T1/E1 Status LED

Dialogic Corporation © 1998-2008board are shown in Figure 5. The TR1034 Fax Board can be inserted into any of the PCI slots shown in Figure 5. Figure

Kommentare zu diesen Handbüchern

Keine Kommentare