Product Series SDK 6.7.0 Release Notes 8
Changes in SDK 6.7.0 (From SDK 6.6.9)
The following section describes the customer-visible issues that have been resolved in this SDK release. The notation
IPYnnnnn” is used to reference a specific issue in Dialogic’s change request tracking database.
Fixed IPY56815 - On occasion, when using the automatic activation method with the SR140 License Manager
application (brktlicmgr.exe), an error dialog would be presented to the user that the “Brooktrout License
Manager has stopped working”. This has been corrected.
Fixed IPY57317 - When starting under Windows, Boston Host Service would search for a hosts file in the
\windows\system32\drivers\etc directory. With some installations of Windows, the hosts file is not present. In
these cases an error is reported in the ECC log and all call control API functions fail. For example,
BfvLineWaitForCall will report a "Not in a Connected State" error. This has been changed to ignore if the
hosts file in the \windows\system32\drivers\etc directory is not present.
Fixed IPY57231 - Under Windows 2012 only, when the driver install program (install.exe) is used to first
install and then remove the device driver, and then subsequently the Device Manager is used to install the
device driver, the Device Manager will display the driver as not digitally signed. Also, some supporting files
will appear to not have been created or installed. This has been fixed.
Fixed IPY57440 -When using 64-bit applications which manipulates TIFF files, under some conditions files
could be read or written improperly. This has been fixed.
Fixed IPY57360 - Under certain conditions when the SR140 sends a G.711 INVITE meessage, if a gateway
uses SIP Early Media and sends a SIP 183 PROGRESS with an SDP followed by a 200 OK also with an SDP,
the SR140 may send a new G.711 INVITE and a BYE message immediately after. The SR140 would report a
final call progress of SIT Reorder. This has been fixed.