1000 and 2000 Media Gateway Series User’s Guide
Parameter Reference
3.9.3 Message Waiting Control Group
The Analog parameters in the Message Waiting Control group include:
MWI Confirmation Tone
Use Same Port for MWI Clear/Set
3.9.3.1 MWI Confirmation Tone
Description: Specifies whether or not the PBX sends a confirmation tone to signal the successful
completion of a Message Waiting Indication (MWI) request.
Allowed Values:
Yes = PBX will send a confirmation tone.
No = PBX will not send a confirmation tone.
Default Value = No
INI File Parameter Name = telMwiConfirm
3.9.3.2 Use Same Port for MWI Clear/Set
Description: Specifies if the PBX requires that the telephony station that set an MWI be used to
clear the MWI.
Note: Some PBX types require that the port that set an MWI be the same port that clears the MWI.
Allowed Values:
Yes = Use the same port to set and clear the MWI.
No = Not necessary to use the same port to clear an MWI that was used to set the MWI.
Default Value = Yes
INI File Parameter Name = telMwiSamePort