2
Ping/Telnet
Be sure that elements of FoIP network can respond to
PING
– NIC on fax server
– Ethernet port on TR1034 IP board (if applicable)
– Media gateway
– IP PBX, SIP proxy/registration server, H.323 gatekeeper (if
www.dialogic.com
Slide 4
applicable)
TELNET over ports that we need free
– 5060 for SIP, 1720 for H.323 (1719 if gatekeeper used),
media port default range 56000-57000
– telnet IPaddress port#
– Simple PING won’t necessarily confirm port availability
Things to Watch Out For on Fax Server….
Anti-virus software
Soft IP phones like SJ Labs’s softphone
Firewall programs (e.g. Windows
®
Firewall)
Occasionally something like one of the above may interfere
with trying to use SR140 on one IP stack but not another
www.dialogic.com
Slide 5
– E.g., channels will fail to reset if SIP chosen but will reset and
be put in-service successfully if H.323 is chosen
FaxVoiceDiag
Free Diagnostic Test Utility from Dialogic
Designed for end-users
Tests Dialogic
®
Brooktrout
®
TR1034 Fax Board/SR140 Fax Software
sending / receiving a fax
– Analog
– T1-ISDN-RBS
www.dialogic.com Slide 6
–E1-ISDN
– IP: Brooktrout TR1034 Fax Board – Dialogic
®
Brooktrout
®
SR140
Fax Software
– Note: If LAN-fax software already installed, this needs to be
stopped
• Only that service which interacts with Dialogic piece
Kommentare zu diesen Handbüchern