FAX BOARDS AND FAX DRIVERS INSTALLATION
52
Keyword Description
Value Type
decimal
Default value
0
missing_wait
Specifies the delay to apply during dialing when the dial string does not contain a w or a , at the
start of the dial string or immediately following an initial 8 or 9 50 ms units.
Value Type
decimal
Default value
20 (1 second)
restrict_res
Specifies allowable resolutions for fax reception.
0 = only 200H x 100V (normal)
1 = 200H x 200V (fine)
2 = 200H x 400V
4 = 300H x 300V
8 = 400H x 400V
Regardless of the value chosen, 200H x 100V (normal) is always allowed.
Value Type
hex
Default value
1
silcompr_start
When silence compression is enabled, silence at the start of recording will be compressed to
the time specified, in milliseconds.
Value Type
decimal
Default value
500
silcompr_middle
When silence compression is enabled, silence in the middle of recording will be compressed to
the time specified, in milliseconds.
Value Type
decimal
Default value
500