Release Notes for *.dc6 code files - V1.10
4
Release Notes for *.dc6 code files - V1.10
1 Overview
This is the first full release of the code file for the Dialogic
®
DSI SS7MDL4
Network Interface Board since V1.08. It contains an important correction to
prevent the board spontaneously shutting down and new functionality to
provide additional control over LIU clock recovery.
The release is fully backwards compatible with the previous release.
1.1 Applicability
All users are advised to upgrade to this release as it includes enhancements
to prevent occasional board shutdown issues.
To benefit from the enhancements contained within, the code file must be
used in conjunction with either the Dialogic
®
DSI SS7 Development Package
for Linux 6.2.0 (or later) or the Dialogic
®
DSI SS7 Development Package for
Solaris 5.0.2 (or later).
1.2 Resolved Customer Issues
Updates to resolve the following customer issues are included in this release:
IPY00091590.
2 New Functionality
2.1 LIU Clock Recovery
This release provides support to optionally exclude individual LIUs from being
considered for clock recovery.
When using s7_mgt, an LIU can be excluded as a source of clock recovery by
setting bit 0 in the <options> parameter in the LIU_CONFIG command.
When using message-based configuration set bit 0 in the ‘clk_opt’ field of the
LIU_MSG_CONFIG message. The ‘clk_opt’ field is a 2 octet parameter
commencing at offset 19.
3 Other Changes
3.1 Board Shutdown (IPY00091590)
Under certain circumstances, the board could spontaneously shutdown,
potentially causing operating system ‘panic’ or ‘confusion’. This code file when
used in conjunction with drivers from the Development Packages listed above
corrects this issue.