DSI SS7MD Programmer’s Manual Issue 3
<gtai_replacement> parameter of the associated SCCP_GTT_ADDRESS command. The mask can
contain the following:
<primary_address_id>
Identifies the SCCP_GTT_ADDRESS command to use as the primary translation.
<backup_address_id>
Identifies the SCCP_GTT_ADDRESS command to use as the backup translation.
Mnemonic Function
- Padding (ignored).
/ Separator used to split the mask into sections.
K or KEEP
The digits in the corresponding section of the global title address
information will be kept as-is.
R or REPLACE
The digits in the corresponding section of the global title address
information will be deleted and the digits in the corresponding section of
the primary or backup address will be inserted in their place.