4.3.4 LIU_MSG_R_CONTROL - LIU Read Control Request
Synopsis
Message sent by the application to read back the current Line Interface Unit
(LIU) control options from the board.
Format
LIU_MSG_R_CONTROL (0x5e38)
liu_id (in the range 0 to one less than the number of LIUs)
Used to request a confirmation.
Parameter area formatted in the same manner as the
LIU_MSG_CONTROL message. All fields should be set to 0.
The confirmation message contains LIU control options.
The user should set the fields to 0 and the module writes the current
control parameters in the confirmation message.
Description
This message is sent to the board to read back the current control parameters selected
for a LIU. The user should always request a confirmation message. The confirmation
message indicates success when the status value of 0 and contains the current control
parameters in the parameter area of the message.