Under Conditions, click Add, and in Called number, enter a regular expression
that matches only the numbers of the Microsoft
®
Office Communications Server
2007 in E.164 format including country code, area code, trunk prefix, and
extension number. In this scenario, the extensions at the Office Communications
Server start with 4 or 5. Within the regular expression, this is represented by
[45].
Click OK to save the settings and close the window.
Create the second route from the Microsoft
®
Office Communications Server 2007 to the
PBX. To do so, click Add in the Routing section, and configure the following
parameters:
Name: Enter a unique name to easily identify the route.
Source: Select the PSTN controller and the SIP peer you configured for the
Microsoft
®
Mediation Server as sources.
Destination: Select the PBX controller as a Master destination.
Number format: Select International number from the dropdown menu.
Encoding: Select Use type flag from the dropdown menu.
Under Conditions, click Add, and in Called number, enter a regular expression
that matches only the subscriber numbers of the PBX in E.164 format including
country code, area code, trunk prefix, and extension number. In this scenario,
the extensions at the PBX start with 2 or 3. Within the regular expression, this is
represented by [23].