Dialogic® Diva® SIPcontrol™ Configuration
27
A restart of Diva SIPcontrol is recommended if you change the IP address or the port
on which SIPcontrol is listening. If you do not restart, Diva SIPcontrol will continue
listening on the previously configured port and IP address.
Note: The restart will terminate active connections.
The names for specific configuration elements are limited to 32 alphanumeric
characters and must not be repeated, i.e., you cannot assign the same name for two
SIP peers.
The configuration session times out after 30 minutes of inactivity and a new login is
required to access the session again. If the new login screen appears when you try
to save the configuration, login again and click the "Back" button of the browser. The
configuration session opens with the settings before the time out and you can save
the configuration.
To restart the Dialogic
®
Diva
®
WebConfig service, in the SIPcontrol web interface,
click System control on the left hand side, and then click Restart in the System
status management section.
Diva SIPcontrol provides a secure configuration via the web interface (HTTPS). The
default port for HTTPS is 10006. Diva SIPcontrol provides a default certificate, but for
security reasons you can install your own webserver certificates. To install a
webserver certificate and corresponding key file, upload and install these files in the
Webserver certificate management section under System Control.
To use TLS for SIP calls, you need to upload the certificates as described under
Security Profiles and enable the TLS port as described under Network Interfaces.
To open the online help for a specific parameter, click the parameter, and a window
with the help text will appear.
Configuring Dialogic® Diva® SIPcontrol™
At a minimum, a Diva SIPcontrol configuration must contain the following components:
At least one enabled network interface
At least one enabled SIP peer
At least one route for PSTN to SIP calls and another route for SIP to PSTN calls
There are four ways to configure Diva SIPcontrol:
Use the Configuration Wizard.
Load an existing configuration profile
Import an existing configuration file
Configure Diva SIPcontrol manually
Using the Configuration Wizard
The easiest way to configure Diva SIPcontrol is to use the Diva SIPcontrol configuration
wizard. The wizard provides a step-by-step interface that helps you generate configurations
for the following use cases:
Empty configuration that resets existing Diva SIPcontrol web interface settings
Simple configuration for a general purpose gateway
DMG4000 hybrid gateway
DMG4000 Survivable Branch Appliance
Kommentare zu diesen Handbüchern