The application software shall comply with the following requirements
before the commencement of dialing:
When dial tone detection is enabled, the application software may
commence dialing after the presence of dial tone is validated.
If dial tone detection is not enabled or if dial tone is not detected, the
application software shall commence dialing no less than 2 seconds
after the line is seized.
A total of 10 call attempts are allowed to a telephone number, with a
minimum period of 2 seconds between calls. If the call does not connect
after 10 attempts, 30 minutes must expire before automatic redialing may
be initiated.
These products must connect to the telecommunications network only by
means of cables that meet applicable ACA standards and
telecommunications conformity.
These products must only be used in a data terminal equipment (DTE),
e.g., computer, that has a screw-down cover or lid. Because unsafe voltages
(TNV) exist on these products, disconnect the product from the telephone
line while the cover of the DTE is removed.
Note: This does not apply to Dialogic
®
Diva
®
V-xPRI PCIe HS and V-xPRI
PCIe FS Media Boards.
These products will not automatically put the channel back to the on-hook
state when the calling party hangs up. The application is tasked to handle
this function on the detection of a disconnect tone or loop current drop.
Regulatory information for Japan
Product Certificate Number
Diva BRI-2
Diva UM-BRI-2
CD-02-0870JP
Diva 4BRI-8
Diva UM-BRI-2
C01-0472JP L01-0152
Diva PRI/E1/T1-CTI
Diva PRI/E1/T1-8
CD05-0558001
Diva PRI/T1-24
Diva PRI/T1-24 PCIe
CD05-0557001
Diva V-2PRI CD06-0488001
Diva V-4PRI CD06-0489001
Diva Analog-4
Diva Analog-8
Diva UM-Analog-4
Diva UM-Analog-8
A05-0055003