Chapter 4 Operation
Table 1. Command Rejection Responses
4.9 FTP Access
The Signaling Gateway supports FTP server operation allowing you to perform maintenance operations, such
as software, license and configuration update without the use of MML as well as providing access to locally
stored continuous records and periodic reports.
An FTP session should be established between the remote machine and the Signaling Gateway by entering
the appropriate command on the remote machine's keyboard, for example:
ftp 123.124.125.125
The FTP server can be activated or deactivated using the FTPSER parameter on the CNSYS command.
The appropriate user name and password to use depends on whether the FTPPWD option has been set to Y
using the CNSYS MML command.
When FTPPWD = Y, FTP access must use the fixed user name “siuftp” in conjunction with the normal MML
access password as configured by setting the CNSYS parameter PASSWORD.
Access to the Signaling Gateway using other user accounts except “siuftp” is denied. Note also that access is
denied if FTPPWD = Y, but there is no MML password.
When FTPPWD=N, no FTP access is permitted. Access with “siuftp” or any other user account is disabled.
Therefore, you are strongly advised to activate FTP password security.
The state of FTPPWD can be viewed using the CNSYP command.
Response Reason for Rejection
CONFIGURATION EXCEEDS
LICENSE LIMITS
The entity being configured exceeds the limits of the license installed
on the system.
EXTRA PARAMETERS Too many parameters have been entered.
GENERAL ERROR
Command unable to execute due to an external error (for example, a
missing or write-protected CDROM).
ILLEGAL COMMAND The command is invalid for the mode of operation.
INCONSISTENT DATA
The values of parameters are inconsistent with each other or with data
already entered into the system.
INCONSISTENT PARAMETER The parameters input are not valid together for the command.
INTERNAL ERROR Command failed to complete due to internal error.
INVALID INDICATOR
This command contains a ‘format character’ (‘:’, ‘;’, etc.) that is not
valid for this command.
INVALID INFORMATION GROUPING
The type of information grouping used in the input of the parameter
value is not valid.
INVALID INFORMATION UNIT The value entered for a parameter is not valid for that parameter.
INVALID PARAMETER NAME A parameter name has been entered that is not valid for this command.
MISSING DATA A parameter has no data.
MISSING PARAMETER A required parameter has not been input.
NO SYSTEM RESOURCES
The requested command cannot be executed due to unavailable system
resources.
RANGE ERROR The value assigned to a numeric parameter is outside the valid range.
UNACCEPTABLE COMMAND
The command is valid but not in the current state of the equipment (for
example, changing a signaling link configuration without blocking).
UNKNOWN COMMAND The command is not recognized.
UNKNOWN SEPARATOR The character used to separate two parameters is not recognized.