Dialogic DSI SS7MD Bedienungsanleitung Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 176
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
51
Dialogic
®
DSI Signaling Server SGW Mode User Manual Issue 5
Examples
ALCLP:CLA=3;
ALCLP:CLA=4;
ALCLP:CLA=5;
ALCLP;
Output Format
Alarm Fault Codes
CODE CLA TITLE
11 4Processor1 fail
EXECUTED
6.4.3 ALFCP – Alarm Fault Code Print
Synopsis
This command gives a printout of the alarm class of the specified fault code(s).
The alarm class (CLA) is used to determine whether the alarm is classed as Minor, Major or Critical and in
turn governs the alarm LED, relay and SNMP alarm that are activated when the condition exists.
Each alarm code (CODE) has a factory-set default class. See Chapter 8, “Alarm Fault Code Listing” for the
factory default for each alarm code.
Syntax
ALFCP[:CODE=…];
Prerequisites
None
Attributes
None
Examples
ALFCP;
ALFCP:CODE=8;
Output Format
Alarm Fault Codes
CODE CLA TITLE
8 4 In-band AIS
EXECUTED
6.4.4 ALLIP – Alarm List Print
Synopsis
This command gives a printout of all ACTIVE fault codes stored in the system’s alarm log.
Each fault code (CODE) is associated with an alarm class (CLA) which may be Minor, Major or Critical. The
alarm class in turn governs which alarm LED, relay or SNMP alarm is activated when the condition exists.
The command provides an indication of the time that the alarm occurred (OCCURRED), the alarm class (CLA
indicating either a System, PCM or signaling failure) as well as an alarm code specific identifier (ID) and
diagnostic field (DIAG).
See Chapter 8, “Alarm Fault Code Listing” for the definitions of the alarm code specific parameters.
Note: The meaning of the ID field depends on the alarm code and is described in Chapter 8, “Alarm
Fault Code Listing”.
Seitenansicht 50