Chapter 6 Command Definitions
Output Format
Configuration SNMP Traps
OBJGRP OBJECT UP DOWN INACTIVE IMPAIR RESTART QUIESCE WARNING
1 1 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
1 2 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
1 3 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
2 1 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
2 2 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
2 3 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
2 4 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
3 1 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
3 2 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
3 3 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
3 4 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
3 5 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
4 1 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
5 1 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
5 2 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
6 1 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
6 2 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
6 3 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
7 1 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
7 2 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
7 3 CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE CHANGE
EXECUTED
6.5.9 CNOBS – Set TRAP Configuration
Synopsis
This command allows a user to determine the conditions under which an SNMP TRAP will be generated for a
particular DSMI object.
Essentially, a TRAP can be generated:
"When any row within an object changes state (CHANGE)
"When a new row (with a particular state) is created within an object (CREATE)
"When a row (with a particular state) is destroyed within an object (DESTROY)
"When any combination of the above occur (ALL), or when an event occurs that affects the alarm
condition of the object, but does not necessarily change the state.
TRAPs can also be completely disabled (NONE).
Possible states that a DSMI object can transition into are:
Only one state's TRAP configuration can be configured per single invocation of this command.
The CNOBP command displays the current TRAP configuration for each object.
These TRAP messages are sent to SNMP managers, which are defined with the CNSMI command. The default
setting for all object states is
CHANGE.
UP Operational and available
DOWN Not available
INACTIVE Operational but not available
IMPAIR Operational and available but encountering service-affecting condition (e.g. congestion).
RESTART Unavailable but will soon be available
QUIESCE Operational but in the process of shutting down/being removed
WARNING Operational and available but encountering a non service-affecting condition