Chapter 5 Parameter Definitions
SEQ Sequence number 1 to 32
SG Reserved
SI Reserved
SIGTYPE
Type of software loaded onto signaling
board
SS7
SLC
Signaling link code uniquely identifying a
signaling link within a link set
0 to 15
SNMP
Whether SNMP should be active on the
system
SNMP version running of the system
Set to DK4032, DSMI or
NONE
SNRT Reserved
SNTYPE
The type of operation of the SIGTRAN
link
One of:
•SGM3UA
•M2PA
SNLINK Logical reference for a SIGTRAN link 1 to 256
SPEED
The speed of an Ethernet port.
The values 10, 100, 100 select 10 MHz,
100 MHz and 1 GHz respectively. An “H”
appended to the value indicates half-
duplex operation; values without the
appended “H” are full-duplex operation.
One of:
•AUTO
10
100
1000
10H
100H
Default = AUTO
SRTX
Number of times a packet of SIGTRAN
information can be retransmitted before
determining that the SIGTRAN link has
gone out of service
2 to 10
SS7MD
SS7 signaling mode:
ITU14 – ITU operation with 14 bit
Point Code
ITU16 – ITU operation with 16 bit
Point Code
ITU24 – ITU operation with 24 bit
Point Code
ANSI – ANSI operation with 24 bit
Point Code
One of:
ITU14
ITU16
ITU24
•ANSI
STS
A timeslot within a PCM interface on a
board used for monitoring information
sent by the monitored object. The format
is:
xx-y-zz
where:
xx = board position (BPOS)
y = PCM within a board
zz = timeslot
xx – 1 to 3
y – 1 to 4
zz – 1 to 31
SUBNET
Subnet mask for the network to which
the Signaling Gateway is connected
specified using dot notation, that is,
www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
Default =
255.255.255.0
SYNCPRI
The priority the PCM is given to provide
clock synchronization:
0 – Indicates never provide clock
synchronization
1 – Highest priority that PCM should
provide clock synchronization
32 – Lowest priority, that is, other
PCMs have precedence
0 to 32 Default = 0
SYSID System identity
0 to 12
<text character>
SYSREF The system reference number 0 to 999 Default = 0
Table 3. Parameter Definitions (Continued)