Dialogic DSI SS7MD Bedienungsanleitung Seite 85

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 176
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 84
85
Dialogic
®
DSI Signaling Server SGW Mode User Manual Issue 5
If an SNLINK is specified, it’s SNTYPE must be M2PA.
If an SNLINK is specified, it must be initiated, blocked and cannot be associated with any other SS7 link.
The command cannot change between SNLINK and EQU type C7LINKs.
SS7 links can use signaling processors 1 to 4 on a Dialogic
®
DSI SPCI4 or SPCI2S Network Interface
Board or 1 to 64 on a Dialogic
®
DSI SS7HDP Network Interface Board.
Attributes
CONFIG
Examples
C7SLC:C7LINK=4,EQU=2-3,TS=3-3-16,M56K=1;
6.6.11 C7SLE – CCS SS7 Signaling Link End
Synopsis
This command is used to end an SS7 signaling link.
Syntax
C7SLE:C7LINK=;
Prerequisites
The signaling link must be blocked.
The signaling link must not be monitored.
Attributes
CONFIG
Examples
C7SLE:C7LINK=1;
6.6.12 C7SLP – CCS SS7 Signaling Link Print
Synopsis
This command is used to obtain a printout of the attributes of SS7 signaling link(s). If no link is specified, all
initialized links are output.
Syntax
C7SLP:[C7LINK=…];
Prerequisites
None
Attributes
None
Examples
C7SLP:C7LINK=1;
C7SLP;
Output Format
Signaling Link Configuration
C7LINK EQU TS SNLINK LS SLC M56K PCR
1 1-1 1-3-16 1 0 0 N
2 1-2 2-3-16 1 1 0 N
3 1 2 0 0 N
4 2 2 1 0 N
EXECUTED
Seitenansicht 84