DSI Signaling Server SGW Mode User Manual Issue 5
SYSTYPE The type of system to be run
One of:
•SGW
•DSC
•SIU
TCOM SNMP Trap Community String
Max 12 alphanumerical
characters
TFORMAT
Format of SNMP trap to be dispatched to
the SNMP manager
1 - SNMP V1
2 - SNMP V2
3 - SNMP V2 INFORM
TIME
Time of day in the format:
xx:yy:zz
where:
xx – 2 digit hour
yy – 2 digit minute
zz – 2 digit second
xx – 00 to 23
yy – 00 to 59
zz – 00 to 59
TLO Auto log off time (in minutes) 1 to 60 Default = 30
TLOW Log off warning time (in minutes) 0 to 60 Default = 25
TMSEC
Timer values in milliseconds associated
with a timer number (resolution is
100ms)
100 to 10000 (in integer
multiples of 100)
TO
Signaling system dependent timer
number.
As specified in the particular signaling
system’s list of timers.
1 to 999
TS
A timeslot within a PCM interface on a
board in the format:
xx-y-zz
where:
xx = board position (BPOS)
y = PCM within a board
zz= Timeslot
xx – 1 to 3
y – 1 to 4
zz – 1 to 31
TSEC
Timer values in seconds associated with
a timer number
1 to 3000
TTYPE
Timer Type
See Section 5.3, “Signaling Gateway
Timers” on page 46 for definitions of
Signaling Gateway “CONV” specific
timers.
One of:
•MTP3
•MTP3A
•SCTP
•CONV
UP SNMP object transition state.
One of:
•All
•Create
•Change
•Destroy
•None
Traps will be generated
if set to All, Create,
Change or Destroy.
Traps will not be
generated if set to
NONE.
Default = Change
Table 3. Parameter Definitions (Continued)