Dialogic DSI SS7MD Bedienungsanleitung Seite 61

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 176
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 60
61
Dialogic
®
DSI Signaling Server SGW Mode User Manual Issue 5
Syntax
CNOBS:OBJGRP=,OBJECT=[,UP=]|[,DOWN=]|[,INACTIVE=]|[,IMPAIR=]|[,RESTART=]|[,QUIESCE=,]|[,WARNING=];
Prerequisites
The DSMI-based SNMP agent must be enabled.
Attributes
CONFIG
Examples
CNOBS:OBJGRP=7,OBJECT=2,DOWN=all;
This will cause a TRAP to be generated whenever an SS7 link is created in the Down state, or destroyed while
in the Down state or when the link enters the Down state.
6.5.10 CNPCI – Configuration PCM Initiate
Synopsis
This command configures a PCM (PCM) for T1 or E1 operation (PCMTYPE) on a board such that it is available
for signaling or voice. The command optionally configures the PCM to be used as a potential synchronization
source for the system (SYNCPRI). The command also allows the frame format (FF) and line code (LC) to be
configured. See Section 7.1.2, “Boards and PCMs” on page 136 for a more detailed description of PCM
configuration.
Syntax
CNPCI:PCM=,PCMTYPE=,[SYNCPRI=,][FF=,][LC=,][IDLE=][BM=][BUILDOUT=,] [UNS=,];
Prerequisites
The board on which the PCM exists has been initiated.
The PCM has not already been initiated.
For a PCMTYPE of E1, the LC can be set to HDB3 and the FF can be set to G704, CRC4, CRC4C or
CRC4G706.
For a PCMTYPE of T1, the LC can be set to AMI or B8ZS and the FF can be set to SF, ESF or CRC6.
An FF of CRC4G706 can only be set on a board type of SS7HDP.
The BUILDOUT parameter can only have a value of 0 for E1 and a value of 1 for T1s on boards of a type
other than SS7HDP.
A frame format of UNS can only be specified for PCMs on SS7HDP signaling boards.
Attributes
CONFIG
Examples
CNPCI:PCM=1-1,PCMTYPE=E1,SYNCPRI=1;
Seitenansicht 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 175 176

Kommentare zu diesen Handbüchern

Keine Kommentare