Dialogic DSI SS7MD Bedienungsanleitung Seite 41

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 176
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 40
41
Dialogic
®
DSI Signaling Server SGW Mode User Manual Issue 5
MASK
IP network mask specified using dot
notation, that is, www.xxx.yyy.zzz
www – 0 to 255
xxx – 0 to 255
yyy – 0 to 255
zzz – 0 to 255
MINREC
The minimum number of records held by
the Signaling Gateway before transfer
100 to 200
MNGR Logical identifier for an SNMP manager. 1 to 32
NA Network appearance 0 to 2147483647
NASP
Number of ASP required in load sharing
mode
0 to 32 Default = 0
NC Signaling Gateway SS7 network context 1 to 4
NI Network Indicator for an SS7 link set 0 to 3
OBJECT
Identifier of a table within a Signaling
Server Group Object.
Refer to Dialogic
®
DSI
Signaling Servers SNMP
User Manual
(U05EPP01) for MIB
details.
OBJGRP
Identifier of the Signaling Server Group
Object in the DSMI MIB.
1 - Management Group
•2 - System Group
3- Platform Group
•4 - IP Group
5- Board Group
•6 - SS7 Group
7 SIGTRAN Group
8 - Access Group.
Refer to Dialogic
®
DSI
Signaling Servers SNMP
User Manual
(U05EPP01) for MIB
details.
OPC SS7 Originating Point Code 0 to 16777215
OTS
The output timeslot in a cross connection
(in the case of a duplex cross connection,
this is also the input timeslot for the
reverse direction). The format is:
xx-y-zz
where:
xx = board position (BPOS)
y = PCM within a board
zz = Timeslot
xx – 1 to 3
y – 1 to 4
zz – 1 to 31
PAGE The page of data to be printed 1 to 10 Default = 1
PARITY
Parity option on V.24 port.
Affects transmit parity only, parity is
ignored on receive.
One of:
ODD
•EVEN
•NONE
Default = NONE
PASSWORD
Used to specify the password for either
remote login access or to provide
password control for Signaling Gateway
MML
0 to 12
<text character>
PCM
PCM interface on a board in the format:
xx-y
where:
xx = board position (BPOS)
y = PCM within a board
xx – 1 to 3
y – 1 to 4
PCMD
Application Server Point Code mode:
ANY – If any Application Server is in
service then the Point Code the
Application Server exists within is
considered to be up.
ALL – Only when all the Application
Servers within a Point Code are in
service will the Point Code they exist
within be considered to be up.
One of:
•ANY
ALL
Table 3. Parameter Definitions (Continued)
Name Description Range Notes